EMC testing
Short service description
The Microwave Laboratory conducts scientific research with electromagnetic radiation in the frequency range from 300 MHz to 100 GHz. The laboratory premises are equipped with a high-quality anechoic chamber measuring 8.5 × 4.6 × 3.8 m, used for measurements in the frequency range from 800 MHz to 20 GHz. This chamber partially complies with the requirements of the IEC EN 61000-4-3 standard for electromagnetic emission tests and fully complies with the requirements for testing the immunity of electronic devices to electromagnetic radiation. The high-power pulse sources available in the laboratory allow the generation of pulses with a power of up to 100 kW.
Service technical information
Radiated emissions in the frequency range from 500 MHz to 1 GHz. Note: Charging mode with any load under which the device operates. Radiated emissions in the frequency range from 1 GHz to 6 GHz. Note: Charging mode with any load under which the device operates. Harmonic current emission up to 25 harmonics (50 hz * 25). Note: Standby mode. Radiated RF electromagnetic field immunity test in the frequency ranges from 500 MHz to 1 GHz with 10 V/m field. Note: Charging mode with any load under which the device operates. Radiated RF electromagnetic field immunity test in the frequency ranges from 1.4 GHz to 2.7 GHz with 10 V/m field. Note: Charging mode with any load under which the device operates.
Service price
1059
Exact service location
Saulėtekio av. 3
Vilnius City
Contact information of the person responsible for providing the service
Karolis Stašys
Contact the company